Frigobase Frigodep Frigodiag Frigolec
: Includes data on environmental impacts, such as Global Warming Potential (GWP) and Ozone Depletion Potential (ODP). 2. Frigodep: System Simulation and Performance
New systems send alerts to your phone: "Evaporator fan drawing high amps. Clean filter." This predictive maintenance prevents catastrophic failure. frigobase frigodep frigodiag frigolec
Imagine a walk-in cooler at 50°F (target 36°F). Frigodep says: "Runtime is 100%." Frigodiag then steps in: Pressures are 55 psig suction / 250 psig discharge on R448A. Target superheat is 8°F, but you measure 2°F. Diagnosis: Overfeeding TXV due to a bulb that has lost its charge or is poorly insulated. Replacement of the TXV power head solves it. : Includes data on environmental impacts, such as